Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,17 +1,12 @@ | ||
## Configuring Automatic Sensitivity Mode | ||
## Configuring Automatic Sensitivity and Meal Assist Mode | ||
|
||
For more information review https://github.com/openaps/oref0/issues/58 | ||
|
||
1) Ensure to get the latest dev branch | ||
``` | ||
cd | ||
cd src | ||
cd oref0 | ||
git pull | ||
git checkout dev | ||
sudo npm install -g | ||
sudo npm install -g git://github.com/openaps/oref0.git'#dev' | ||
``` | ||
Make sure you run the last line to install the tools | ||
|
||
|
||
2) Next in order to properly execute the new auto-sensitivity module, you need to have at least 24 hour worth of pump history data and enough bg readings (past 24 hours). | ||
In your openaps.ini apply the following changes: | ||
|
@@ -24,6 +19,11 @@ count = 288 | |
``` | ||
|
||
Note: If using Nightscout add count=288 to your entries.json API call as a querystring parameter | ||
|
||
One way to do this is to go to your openaps directory and do: | ||
|
||
`nano ns-glucose.ini` | ||
this opens the file in the Nano editor which allows you to make these changes: | ||
For NS it will look something like this depending on how you implement it (note the ?count=288) that is what you have to add | ||
``` | ||
[device "curl"] | ||
|
@@ -36,34 +36,45 @@ args = -c "curl -s https://[Your URL]/api/v1/entries.json?count=288 | json -e 't | |
|
||
If your [glucose.json] does not have enough entries you will see a warning when running your auto-sens.json report "Error: not enough glucose data to calculate autosens." | ||
|
||
3) After applying the above change you need to add a new device and report as follow: | ||
3) After applying the above change you need to add a new device and report. | ||
A process device must be added, call it "auto-sense" | ||
|
||
`openaps device add auto-sens process --require "glucose pumphistory insulin_sensitivities basal_profile profile" oref0 detect-sensitivity` | ||
|
||
Inspecting openaps.ini with | ||
|
||
`less openaps.ini` will reveal | ||
|
||
``` | ||
[device "auto-sens"] | ||
vendor = openaps.vendors.process | ||
extra = auto-sens.ini | ||
``` | ||
and your auto-sens.ini should look like this: | ||
and your auto-sens.ini using `less auto-sens.ini` should look like this: | ||
``` | ||
[device "auto-sens"] | ||
fields = glucose pumphistory insulin_sensitivities basal_profile profile | ||
cmd = oref0 | ||
args = detect-sensitivity | ||
``` | ||
|
||
4) Next create this report | ||
4) Next create this report. The easiest method is to | ||
|
||
`nano openaps.ini` cut and paste: | ||
``` | ||
[report "[Your Path]/auto-sens.json"] | ||
profile = [Your Path]/profile.json | ||
[report "monitor/auto-sens.json"] | ||
profile = settings/profile.json | ||
use = shell | ||
reporter = text | ||
json_default = True | ||
pumphistory = [Your Path]/pump-history-zoned.json | ||
basal_profile = [Your Path]/active-basal-profile.json | ||
insulin_sensitivities = [Your Path]/insulin-sensitivities.json | ||
glucose = [Your Path]/ns-glucose.json | ||
pumphistory = monitor/pumphistory_zoned.json | ||
basal_profile = settings/basal_profile.json | ||
insulin_sensitivities = settings/insulin_sensitivities.json | ||
glucose = monitor/ns-glucose.json | ||
device = auto-sens | ||
remainder = [] | ||
``` | ||
Invoke the report to debug. If you used different conventions than listed above the report will return errors that you will be able to recognize | ||
|
||
5) Next we need to pass auto-sens.json to oref0-determine-basal.json, in openaps.ini add a new input simillar to folowing example below: | ||
``` | ||
|
@@ -72,7 +83,11 @@ fields = iob current-temps glucose profile auto-sens meal | |
cmd = oref0-determine-basal | ||
vendor = openaps.vendors.process | ||
args = | ||
``` | ||
|
||
Note that in the "fields" above that "meal" should only be present if meal assist is configured | ||
|
||
``` | ||
[report "enact/suggested.json"] | ||
profile = [Your Path]/profile.json | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Might want to change the [Your Path] here... |
||
use = shell | ||
|
@@ -84,6 +99,7 @@ glucose = [Your Path]/glucose.json | |
meal = [Your Path]/meal.json | ||
auto-sens = [Your Path]/auto-sens.json | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. ... and here like you did elsewhere. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Great job @ddaniels1 with updates, one thing I would add is to make sure people double check their full path comparing to guide, reason I originally put [Your Path] :) |
||
``` | ||
As per the comment with the device, "meal" should be deleted if meal assist is not activated | ||
|
||
6) Next you have to make sure you pull 28 hours (24h + DIA) of pump history. Change the hours to 24, so your pump history report should look like this: | ||
``` | ||
|
@@ -93,6 +109,14 @@ hours = 28 | |
use = iter_pump_hours | ||
reporter = JSON | ||
``` | ||
|
||
Based on the configuration of the basic loop, suggest that the invoking the monitor/auto-sens.json be added to the gather-profile alias: | ||
`gather-profile report invoke settings/settings.json settings/bg_targets.json settings/insulin_sensitivities.json settings/basal_profile.json settings/profile.json monitor/auto-sens.json` | ||
|
||
and that the gather alias be adjusted to make sure gather-profile is at the end. This is because the monitor/auto-sens.json report depends upon elements from the preceding two aliases to run. | ||
|
||
`gather ! bash -c "rm -f monitor/*; openaps monitor-cgm && openaps monitor-pump && openaps gather-profile"` | ||
|
||
Note. Your loop should run without auto-sens.json report but if you don't pass that as an input you will see the following message while executing oref0-determine-basal.js: | ||
|
||
Optional feature Auto Sensitivity not enabled: { [Error: ENOENT: no such file or directory, open 'online'] errno: -2, code: 'ENOENT', syscall: 'open', path: 'online' } | ||
|
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,18 @@ | ||
Set up Autosensitivity mode prior to meal assist. This includes pulling dev branch and creating the devices and modifications to reports from the basic setup that will be needed for meal assist. | ||
|
||
Be sure | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. This looks incomplete. Did you mean to include this, or was this an aborted effort from before you decided to consolidate them? There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Yes abort it Sent from my iphone
|
||
|
||
|
||
``` | ||
[device "oref0-determine-basal"] | ||
fields = iob current-temps glucose profile auto-sens meal | ||
cmd = oref0-determine-basal | ||
vendor = openaps.vendors.process | ||
args = | ||
``` | ||
|
||
|
||
|
||
|
||
|
||
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
No "e" on auto-sens.